African Journal of Paediatric Surgery About APSON | PAPSA  
Home About us Editorial Board Current issue Search Archives Ahead Of Print Subscribe Instructions Submission Contact Login 
Users Online: 1116Print this page  Email this page Bookmark this page Small font size Default font size Increase font size 
 
ORIGINAL ARTICLE
Year : 2015  |  Volume : 12  |  Issue : 4  |  Page : 232-235

Adding a custom made pressure release valve during air enema for intussusception: A new technique


Department of Surgery, Paediatric Surgery Unit, Faculty of Medicine, Zagazig University, Zagazig, Egypt

Correspondence Address:
Dr. Hosni Morsi Ahmed
Department of Surgery, Paediatric Surgery Unit, Faculty of Medicine, Zagazig University, Zagazig 44519
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0189-6725.172550

Rights and Permissions

Background: Non-surgical reduction remains the first line treatment of choice for intussusception. The major complication of air enema reduction is bowel perforation. The authors developed a custom made pressure release valve to be added to portable insufflation devices, delivering air at pressures accepted as safe for effective reduction of intussusception in children under fluoroscopic guidance. The aim of this study was to develop a custom made pressure release valve that is suitable for the insufflation devices used for air enema reduction of intussusception and to put this valve into regular clinical practice. Materials and Methods: An adjustable, custom made pressure release valve was assembled by the authors using readily available components. The valve was coupled to a simple air enema insufflation device. The device was used for the trial of reduction of intussusception in a prospective study that included 132 patients. Results: The success rate for air enema reduction with the new device was 88.2%. The mean pressure required to achieve complete reduction was 100 mmHg. The insufflation pressure never exceeded the preset value (120 mmHg). Of the successful cases, 58.3% were reduced from the first attempt while 36.1% required a second insufflation. Only 5.55% required a third insufflation to complete the reduction. In cases with unsuccessful pneumatic reduction attempt (18.1%), surgical treatment was required. Surgery ranged from simple reduction to resection with a primary end to end anastomosis. No complications from air enema were recorded. Conclusions: The authors recommend adding pressure release valves to ensure safety by avoiding pressure overshoot during the procedure.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2901    
    Printed54    
    Emailed0    
    PDF Downloaded15    
    Comments [Add]    

Recommend this journal