CASE REPORT
Year : 2017  |  Volume : 14  |  Issue : 4  |  Page : 74-78

Let us save the brain with cerebral oximeter: Two case reports


1 Department of Anesthesiology and Reanimation, Faculty of Medicine, Duzce University, Duzce, Turkey
2 Department of Pediatric Surgery, Faculty of Medicine, Duzce University, Duzce, Turkey

Correspondence Address:
Dr. Ilknur Suidiye Seker
Department of Anesthesiology and Reanimation, Faculty of Medicine, Duzce University, Konuralp, Duzce 81620
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ajps.AJPS_117_16

Rights and Permissions

In the neonates, tracheal atresia and tracheoesophageal fistula (TEF) surgery may result in hemodynamic instabilization, leading to cerebral perfusion insufficiency due to the retraction of the pulmonary vessels and truncus brachiocephalicus. We represented one male and one female neonates which were performed thoracoscopic primary repair of TEF through right thoracotomy at the 3th and 4th postpartum day. Anesthesia was induced using sodium thiopental (5 mg/kg), fentanyl 4 mcg, and rocuronium (0.5 mg/kg) given through intravenous route. Sevoflurane 2% and 50% O2in air were used for the maintenance therapy. During the right lung compression to expose posterior esophagus, no value was observed on the pulse oximeter (PO) probe placed on the right hand, and radial artery was not palpated. At the same time, oxygen saturation was observed as 96%–97% on the left foot probe. As the right cerebral oximeter values (rSO2) were rapidly decreased to 31%, the lung compression was ceased. Right pulse oximeter and right rSO2measurements return to the baseline levels. For the second case - different from the first case -both left and right rSO2was rapidly decreased to 40% levels and return to the baseline levels after was removed the retractors. Right PO and right and left cerebral rSO2values returned to baseline immediately when the retractor compression was ended During the operations involving the great vessels in neonates, cerebral perfusion could be preserved using cerebral oximeter. Cerebral oximeter is more efficient than pulse oximeter for detecting cerebral tissue oxygenation and could be helpful to minimize neuronal damage in the neonates.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed619    
    Printed26    
    Emailed0    
    PDF Downloaded11    
    Comments [Add]    

Recommend this journal